Skip to content
Article

Your First Study: Build a TAM Survey and Run CFA and SEM

By Andrzej Szymkowiak · September 2026

Technology Acceptance Model study

Andrzej Szymkowiak · Last reviewed September 2026

A fitted Technology Acceptance Model in Explonia: ease of use and usefulness drive attitude and intention to use, shown with standardized path coefficients.

TL;DR: A basic Technology Acceptance Model (TAM) questionnaire measures four constructs: perceived usefulness, perceived ease of use, attitude toward using and behavioral intention to use, with three or four 7-point Likert items each (14 items here). This walkthrough builds that survey, collects it on Prolific, and runs CFA and CB-SEM on the same 521 complete responses from simulated data. The CFA fit well (CFI = .985, RMSEA = .034), every construct cleared the usual reliability and validity thresholds, and four of the five TAM paths were significant.

This is a full walk-through of a first quantitative study, from a blank page to a fitted structural model. We will build a survey based on the Technology Acceptance Model (TAM), add validated items from the library, customize them, preview the respondent experience, set up data collection on Prolific, and finish with confirmatory factor analysis (CFA) and covariance-based structural equation modeling (CB-SEM), all in one tool, with no export to a separate statistics package. If you are still working out your research question or questionnaire structure, see research question to questionnaire first.

The numbers and figures below come from a simulated dataset (556 responses generated from a known TAM structure). We use simulated data so you can follow every step without spending money on data collection. On a real study, the steps are identical; only the responses differ.

What is the Technology Acceptance Model?

TAM explains why people adopt a new technology. In its common form it has four constructs:

  • Perceived Ease of Use (PEOU) - how effortless the technology feels.
  • Perceived Usefulness (PU) - how much it helps you do your work.
  • Attitude Toward Using (ATT) - your overall evaluation of using it.
  • Behavioral Intention (BI) - how likely you are to use it.

The classic paths are simple: ease of use feeds usefulness and attitude; usefulness and attitude feed intention. Each construct is measured with several Likert items, which makes TAM a clean example for CFA and SEM.

Step 1: Create the study

Open the Studies page and click New study. Give it a name, here Technology Acceptance (TAM), and pick the language. You start from a blank study.

Creating a new study in Explonia.

That is the whole setup. There is no project wizard to fight through, so you land straight in the builder.

Step 2: Add validated items from the library

You do not have to type your TAM items by hand. Open a section, click the library button, and search the scale library for TAM - Technology Acceptance Model (Davis, 1989). For constructs not in the library, see how to find a validated scale for guidance on sourcing validated batteries from the literature.

Loading the validated TAM scale from the library.

The scale loads four constructs as 7-point Likert matrices: Perceived Usefulness (PU), Perceived Ease of Use (PEOU), Attitude Toward Using (ATT), and Behavioral Intention to Use (BI). Each one carries several items and a clean variable name (PU1, PU2, …). The usefulness and ease-of-use items come from Davis (1989). That paper developed the usefulness and ease-of-use scales. It had no attitude scale, and its outcome was self-reported and self-predicted use. The attitude and intention constructs come from Davis, Bagozzi, and Warshaw (1989), so check where the attitude and intention items in your version come from and cite that source in your Methods section. You can append the scale to the section or replace what is already there.

The items ship with a generic placeholder, [the system], so the battery fits any technology before you adapt it:

The loaded battery: several items per construct, each carrying the generic technology placeholder.

Variable names matter later: they become the column headers in your data and the labels the analysis uses to group items into factors. The library names already follow a prefix convention (PU1, PU2, …), which the analysis step reads automatically.

Step 3: Customize the items

The library gives you a starting point, not a cage. The first thing to do is replace the [the system] placeholder with your own technology. Here that is Explonia, so PEOU1 now reads "Learning to use Explonia would be easy for me." Every item is editable, so you can also:

  • rewrite the wording to fit your technology,
  • trim or add items (keep at least three per construct, see the note below),
  • change the number of scale points and the anchor labels,
  • rename variables, mark items required, or add display logic.
The same battery after replacing the placeholder with the technology name (Explonia).

A small but useful habit: keep your construct prefixes consistent (all ease-of-use items start with PEOU). It keeps the data tidy and lets the analysis build the measurement model for you.

Before you launch, check three things

  • Add a short consent and instructions screen at the start. Participation should be voluntary and anonymous.
  • Keep at least 3 items per construct. A reflective latent factor needs three indicators to be identified in CFA and SEM (with two, a factor on its own is under-identified), and you need several items to estimate reliability (α, CR) and to drop a weak item while keeping enough. Three to six items per construct is the usual range, and the TAM battery here uses three or four. When you develop a new scale, Hinkin (1998) suggests four to six items per construct in the final scale, and writing about twice as many items at the start, so that weak items can be dropped.
  • Trim everything else: cut redundant questions and demographics you will not analyze. Within that limit, a shorter survey gives better data.

Step 4: Preview the respondent experience

Click Draft preview to see exactly what a participant sees. Preview runs the real respondent view, including required-field checks and display logic. Switch between Desktop and Mobile. Many participants answer on a phone, so the mobile layout is worth a look.

Desktop preview of the TAM matrix as a respondent sees it.
Mobile preview in a phone frame.

Preview does not save responses, so you can click through as many times as you like.

Step 5: Set up collection on Prolific

When the survey is ready, you recruit participants. Explonia connects to Prolific from inside the panel, so you do not copy links back and forth. Open the Recruitment tab: each live study has two buttons, Commission pilot (a small test run) and Commission main run (the full sample).

The Recruitment tab, where each live study offers "Commission pilot" or "Commission main run".

Either button opens a short wizard that asks for a description, the number of participants, the reward, and quality filters, and shows the total cost before anything is charged. For guidance on how many participants to target, see sample size before data collection. For a step-by-step guide to Prolific settings and filters, see recruiting participants on Prolific. The wizard ends on a summary. You can Create draft, which prepares the study on Prolific without charging you. Only the separate Publish action starts paid recruitment. For this tutorial we stop at the draft.

The final summary. "Create draft" prepares the study with no charge; only "Publish" spends money.

On a real study, once you publish, responses flow back into Explonia automatically, tagged with their Prolific IDs and approval state. For this walk-through we use a simulated set of 556 responses so we can move straight to analysis.

Step 6: Decide which responses go into the analysis

Before any model runs, settle one question: which rows count? Explonia stores every response with a status. In this dataset the 556 responses break down as follows.

Response statusCountIn the analysis?
Complete521yes (default)
Partial (stopped part way)18no
Screened out or rejected17no

The Sample tab in every analysis carries this filter, and it keeps completed responses only by default. That gives N = 521 for this study. Set it once and leave it alone, because the filter applies to every model you run on that dataset.

This matters more than it looks. If you run the measurement model on one set of rows and the structural model on another, the two sets of fit indices are no longer comparable, and a reviewer who adds up your numbers will notice. Check the N printed on each analysis card and make sure they agree. Note also that none of the 14 TAM items has a missing answer here, so listwise deletion removes nothing; the 35 excluded rows are excluded because of their status, not because of missing data. On a real study with item-level missing data you would see a second, smaller drop, and you should report both numbers.

Step 7: Confirmatory factor analysis (CFA)

With the sample settled, open Analyses and create a new analysis. On the CFA tab, click Suggest from names: the builder reads your variable prefixes and proposes the four-factor measurement model (PEOU1-4 → PEOU, PU1-4 → PU, ATT1-3 → ATT, BI1-3 → BI). Adjust if needed, then Run CFA.

Building the four-factor CFA model with "Suggest from names".

The analysis runs in your browser. On the 521 complete responses, the measurement model fit well: χ²(71) = 114.94, p < .001.

Fit indexValueReading
CFI.985good (≥ .95)
TLI.981good (≥ .95)
RMSEA.034 [90% CI .022, .046]good (≤ .06)
SRMR.028good (≤ .08)
CFA model fit results for the Technology Acceptance Model (TAM) study: CFI, TLI, RMSEA, SRMR, and factor loadings.

Standardized factor loadings ranged from .66 to .79, so each item loaded clearly on its intended construct.

The number that matters most is the standardized loading (β), which says how strongly each item reflects its construct. Here it is for all 14 items; every estimated loading is significant (all p < .001). One item per construct (PEOU1, PU1, ATT1, BI1) is the reference indicator that fixes the construct's scale, so it has no standard error or p value:

Constructβ (standardized)Itemp
Perceived Ease of Use.70PEOU1—
Perceived Ease of Use.79PEOU2< .001
Perceived Ease of Use.66PEOU3< .001
Perceived Ease of Use.75PEOU4< .001
Perceived Usefulness.79PU1—
Perceived Usefulness.69PU2< .001
Perceived Usefulness.77PU3< .001
Perceived Usefulness.68PU4< .001
Attitude.70ATT1—
Attitude.75ATT2< .001
Attitude.75ATT3< .001
Behavioral Intention.74BI1—
Behavioral Intention.73BI2< .001
Behavioral Intention.72BI3< .001

Reference indicator: unstandardized loading fixed at 1.000, so no standard error or p value is estimated; standardized loadings are reported for all items.

The reliability and validity table is computed at the same time:

ConstructαωCRAVE
Perceived Ease of Use.81.82.82.53
Perceived Usefulness.82.82.82.54
Attitude.77.78.78.53
Behavioral Intention.77.77.77.53

McDonald's ω and CR are identical here because both are computed from the same CFA loadings. Report ω or CR next to α, because α assumes that all items load equally well.

All constructs cleared the usual thresholds: Cronbach's α, McDonald's ω and composite reliability (CR) above .70, average variance extracted (AVE) above .50. Discriminant validity held as well, because every HTMT ratio was below .85. Report the highest one rather than a bare "all below .85": here it is .82, for attitude with intention. That is inside the threshold, but close enough that a reviewer may ask whether the two constructs are really distinct, so say what you think and why.

Reliability and HTMT discriminant validity results for the Technology Acceptance Model (TAM) CFA.

If you want the background on any of these, see our notes on confirmatory factor analysis, reliability (α, CR, AVE), and HTMT discriminant validity.

Step 8: CB-SEM, the structural model

CFA tells you the items measure what they should. CB-SEM tests how the constructs relate. On the CB-SEM tab, keep the same measurement model and draw the structural paths: PEOU → PU, PEOU → ATT, PU → ATT, PU → BI, and ATT → BI. The path diagram is interactive, and you can export it as PNG, JPG, SVG or PDF for a manuscript.

CB-SEM results for the Technology Acceptance Model (TAM) study: Article description and interactive path diagram.

The sample is the same 521 responses, and the items are the same 14. That is deliberate, and it is what makes the two sets of numbers comparable:

ModelNχ²dfCFITLIRMSEASRMR
CFA (measurement)521114.9471.985.981.034.028
CB-SEM (structural)521115.5672.985.981.034.028

Read that table as a check, not just as a result. The structural model uses the same items and the same four factors as the CFA, and it only replaces the free correlations between factors with a smaller set of directed paths. In other words, it is nested inside the CFA: it can spend fewer parameters, never more. So its χ² can only go up and its df can only go up, and a structural model that fits clearly better than its own measurement model is a sign that something differs between the two runs, usually the sample or the item list. Here the difference is one degree of freedom and Δχ²(1) = 0.63, p = .43, so dropping the direct PEOU → BI path costs nothing, and the two rows agree to three decimals. That is what a healthy pair looks like.

Pathβ (standardized)p
PEOU → PU.608< .001
PEOU → ATT.231< .001
PU → ATT.582< .001
ATT → BI.757< .001
PU → BI.081.298

Four of the five paths are significant. The model explained meaningful variance in each downstream construct: R² = .37 for usefulness, .56 for attitude, and .67 for intention.

The one path that did not reach significance is worth a sentence of its own, because it is the interesting part. The direct effect of usefulness on intention is small and non-significant (β = .081, p = .298), while the indirect effect through attitude is large and significant (β = .441, p < .001), giving a total effect of .521. Usefulness still drives intention, but it does so through attitude rather than around it. A non-significant direct path next to a strong indirect one is evidence of mediation, not evidence that the predictor does not matter, and writing it up that way is more accurate than deleting the path and pretending you never drew it. For how to test and report an indirect effect like this one, see full vs partial mediation.

Step 9: The Article description

Every analysis screen also carries an Article description box. Explonia drafts a results paragraph in APA style, using your actual numbers: fit indices, significant paths, effect sizes. You copy it, edit it to match your voice, and keep it as your own:

A covariance-based SEM was estimated by maximum likelihood (N = 521). The model showed the following fit: χ²(72) = 115.564, p < .001; CFI = .985; TLI = .981; RMSEA = .034 [90% CI .022, .045]; SRMR = .028. Significant structural paths: Ease of Use → Usefulness (β = .608, p < .001); Ease of Use → Attitude (β = .231, p < .001); Usefulness → Attitude (β = .582, p < .001); Attitude → Intention (β = .757, p < .001).

It is a draft, not a final paragraph. It lists the paths that reached significance, so add the non-significant one yourself, together with the mediation reading above, before this goes anywhere near a manuscript.

What to put in your Methods section

For a study like this, a Methods section would report:

  • Sample and collection: 556 responses collected through Prolific; 521 complete responses analyzed after 18 partial and 17 screened-out responses were excluded; voluntary, anonymous participation.
  • Measures: four TAM constructs (PEOU, PU, ATT, BI) on 7-point Likert scales; items from a validated battery.
  • Analysis: CFA and CB-SEM with maximum likelihood estimation on the same 521 cases; reliability via α and CR; convergent validity via AVE; discriminant validity via HTMT; model fit via CFI, TLI, RMSEA, and SRMR.

For thresholds and reporting conventions, see how to report CFA results in APA and reporting SEM fit indices. Because all four constructs come from the same questionnaire, reviewers may also ask about common method bias, so plan for that question at the design stage: common method bias: prevention beats detection →.

Conclusion

One tool took us from a blank study to a fitted structural model: build with validated items, preview, recruit on Prolific, and run CFA and CB-SEM on the same screen and the same sample. The measurement model was reliable and valid, and the structural paths mostly matched TAM theory, with usefulness reaching intention through attitude. Because the analysis runs in your browser, your response data is not sent to a server to be analysed. The responses themselves are stored securely in the EU.

Remember: the dataset here is simulated for teaching. Your real results will differ, but the workflow, and the publication-ready output, will be the same.

Common mistakes to avoid

  • Running the measurement model and the structural model on different response filters, which gives two different N and makes the fit indices incomparable.
  • Reporting a structural model that fits better than its own CFA; the structural model is nested in the measurement model, so on one sample this cannot happen.
  • Confusing an excluded response with a missing answer; dropping partial or screened-out rows is a sampling decision, listwise deletion is a missing-data decision, and both belong in Methods.
  • Calling a non-significant direct path a failure without checking the indirect effect first, because full mediation looks exactly like this.
  • Writing "all HTMT below .85" and stopping there instead of giving the highest value, which here is .82 and still worth a comment.
  • Treating cross-sectional TAM paths as causal; the design supports association, so write "consistent with" rather than "causes".

Frequently asked questions

Do I need a separate statistics package for CFA and SEM?

No. CFA and CB-SEM run inside Explonia, in your browser. You get loadings, reliability, AVE, HTMT, fit indices, path coefficients, and a draft APA paragraph without exporting to another program.

Why does my CFA report a different N than my SEM?

Almost always because the two analyses use different response filters, not because of missing data. Open the Sample tab on each analysis, match the filters, and rerun. If item-level missing data is the real cause, say so in Methods and report both numbers.

Can a structural model fit better than the measurement model it came from?

Not on the same items and the same sample. The structural model is nested in the CFA, so its χ² and df can only go up. A better-fitting structural model means the two runs differ somewhere, usually in the sample.

Is the data in this tutorial real?

No. It is simulated from a known TAM structure so the tutorial is free to follow. The steps are identical for a real study.

Can Explonia run the whole study, from questionnaire to fitted SEM?

Yes. You build the questionnaire, recruit through Prolific in the panel, then run CFA, CB-SEM, reliability, and HTMT on the collected responses, and export the data to SPSS, R, or AMOS if you want to check the numbers elsewhere.

References

Davis, F. D. (1989). Perceived usefulness, perceived ease of use, and user acceptance of information technology. MIS Quarterly, 13(3), 319-340. https://doi.org/10.2307/249008

Davis, F. D., Bagozzi, R. P., & Warshaw, P. R. (1989). User acceptance of computer technology: A comparison of two theoretical models. Management Science, 35(8), 982-1003. https://doi.org/10.1287/mnsc.35.8.982

Henseler, J., Ringle, C. M., & Sarstedt, M. (2015). A new criterion for assessing discriminant validity in variance-based structural equation modeling. Journal of the Academy of Marketing Science, 43(1), 115-135. https://doi.org/10.1007/s11747-014-0403-8

Hinkin, T. R. (1998). A brief tutorial on the development of measures for use in survey questionnaires. Organizational Research Methods, 1(1), 104-121. https://doi.org/10.1177/109442819800100106

Hu, L., & Bentler, P. M. (1999). Cutoff criteria for fit indexes in covariance structure analysis. Structural Equation Modeling, 6(1), 1-55. https://doi.org/10.1080/10705519909540118

Maxwell, S. E., & Cole, D. A. (2007). Bias in cross-sectional analyses of longitudinal mediation. Psychological Methods, 12(1), 23-44. https://doi.org/10.1037/1082-989X.12.1.23


How Explonia does this for you

Explonia keeps the sample decision in one place: the Sample tab sets the response filter, and every model on that dataset inherits it, so your CFA and your CB-SEM cannot drift onto different N by accident. The Article description box then drafts the APA paragraph from the numbers actually estimated, and you stay the author of every sentence you keep. When you want to verify the estimates elsewhere, the data exports to SPSS (.sav), R, and AMOS, and the model exports as an R script for lavaan. Our validation page shows how the engine's output compares with R.


Ready to run your own study end to end? Build it, collect it, and run real CFA and SEM on your own data, with a draft APA paragraph you can edit. Start free →

How to cite this article

If this article helped your research, you can cite it (APA 7):

Szymkowiak, A. (2026). Your First Study: Build a TAM Survey and Run CFA and SEM. Explonia. https://explonia.com/blog/first-study-tam-cfa-sem/

Last updated: September 2026

Run your whole study in one place

Design it, collect it, and run real CFA and SEM on your own data — with a draft APA paragraph you can edit. Free to start.

Start free